TracePlus®/Win32 Update
|

|
TracePlus®/Win32 version 5 is available for $80.00 for
customers that have version 4.x.x.
TracePlus®/Win32 version 5 is available for $100.00 for
customers that have version 3.x.x.
|
Release Date: 10/24/2008 (Only for customers who have
version 5.x.x)
Version 5.60.000
|
The patch below will only update retail versions of TracePlus®/Win32
.
NOTE: If you are having problems installing the patch over your currently
installed version (listed below), follow the following procedure.
-
Uninstall the product you currently have installed (be sure you
have a copy of the original product you purchased).
-
Reinstall the original version you received when you purchased the
product.
-
Reapply the patch you downloaded from here.
|
HTTP
FTP
The updater will upgrade the following versions of TracePlus/Win32:
-
TracePlus/Win32 v5.01.000
-
TracePlus/Win32 v5.02.000
-
TracePlus/Win32 v5.03.000
-
TracePlus/Win32 v5.04.000
-
TracePlus/Win32 v5.05.000
-
TracePlus/Win32 v5.11.000
-
TracePlus/Win32 v5.12.000
-
TracePlus/Win32 v5.15.000
-
TracePlus/Win32 v5.20.000
-
TracePlus/Win32 v5.25.000
-
TracePlus/Win32 v5.26.000
-
TracePlus/Win32 v5.30.000
-
TracePlus/Win32 v5.32.000
-
TracePlus/Win32 v5.35.000
-
TracePlus/Win32 v5.36.000
-
TracePlus/Win32 v5.37.000
-
TracePlus/Win32 v5.40.000
-
TracePlus/Win32 v5.50.000
-
TracePlus/Win32 v5.51.000
-
TracePlus/Win32 v5.52.000
-
TracePlus/Win32 v5.58.000
The patch includes all bug fixes up to 10/24/2008. We recommend that you apply
this patch so that TracePlus®/Win32 can operate at its maximum
efficiency.
To apply the patch, unzip this file to a temporary directory and run SETUP.EXE
from Windows.
|
If you cannot find the version number of your product in this list,
or the update does not work with your product, please e-mail
for a new copy of SETUP.EXE.
Please note that in order to receive a new copy of SETUP.EXE, you
must provide us with a copy of the original SETUP.EXE from your purchased copy
of the product.
|
Version History
Version 5.60.000 of TracePlus®/Win32 includes the
following fixes and enhancements:
-
The "Open" option was not appearing on the File menu. (FIXED)
-
When saving a view as HTML, the application would crash. (FIXED)
Version 5.58.000 of TracePlus®/Win32 includes the
following fixes and enhancements:
-
Updated to better compatibility with dual-core, quad-core, and 8-core
processors.
-
Updated email activation dialog boxes for better explain how the eamil
activation process works.
-
User interface has been changed to MDI (Multiple Document Interface)
to facilitate easier cross-referencing of information. The following views
display in separate windows: (NEW)
| Diagnostics View |
| SQL View |
| Status View |
| File I/O View |
| Registry View |
-
Comprehensive tutorial for both new and experienced users. (NEW)
-
Added a second toolbar below the main toolbar which contains the following
navigation buttons: (NEW)
| Move to First Item |
Move to First Selected Item |
Move to First Highlighted Item |
| Move to Previous Item |
Move to Previous Selected Item |
Move to Previous Highlighted Item |
| Move to Next Item |
Move to Next Selected Item |
Move to Next Highlighted Item |
| Move to Last Item |
Move to Last Selected Item |
Move to Last Highlighted Item |
-
Added a new View menu containing navigation shortcuts for the Diagnostics View
and the SQL View. (NEW)
-
Added the ability to locate a specific item in the Diagnostics View by entering
a sequence number. (NEW)
-
A "Select Related Items" feature has been added to the Edit menu which selects
groups of objects in the Diagnostics View by the following criteria: (NEW)
| By Conversation |
Has Content-Range Field |
Has Proxy-Authenticate Field |
| HTTP Method |
Has Cookies Field |
Has Proxy-Authorization Field |
| Process ID |
Has ETag Field |
Has Transfer-Encoding Field |
| Remote Address |
Has Expires Field |
Non-cached Responses |
| Remote Port |
Has If-Match Field |
POST Methods |
| Thread ID |
Has If-Modified-Since Field |
Responses with Status Code 2xx |
| Chunked Encoding |
Has If-None-Match Field |
Responses with Status Code 3xx |
|
GET Methods With Parameters |
Has If-Range Field |
Responses with Status Code 4xx |
|
Gzip Encoding |
Has If-Unmodified-Since Field |
Responses with Status Code 5xx |
|
Has Age Field |
Has P3P Field |
SSL Encrypted |
|
Has Authorization Field |
Has PICS-Label Field |
|
|
Has Cache-Control Field |
Has Pragma Field |
|
-
Added the ability to hide selected items and unhide items in the Diagnostics
View. (NEW)
-
Added a "Hide Conversation" option to the Edit menu which hides methods and
responses in the Diagnostics View that are part of a conversation as described
by the selected method or response. (NEW)
-
Added the ability to highlight items in the Diagnostics View with a fixed color
for later reference. The status of all highlighted items can be saved to disk.
The following items have been added to the Edit menu:
| Toggle Highlight |
| Highlight Selected Items |
| Highlight All Items |
| Reset Highlighted Items |
Version 5.40.000 of TracePlus®/Win32 includes the
following fixes and enhancements:
-
Drag and drop applications and documents from the Windows Desktop, Start Menu,
and folders onto the application main window in order to launch them from
TracePlus. (NEW)
-
TracePlus has been modified to run with standard permissions instead of with
administrator privileges in Vista. (NEW)
-
If the target application is Internet Explorer and TracePlus is running with
standard user permissions under Vista, Protected Mode must be turned off. (NEW)
-
Applications requiring adminstrative rights will cause a warning message to
appear in TracePlus if TracePlus is not running with administrative rights. (NEW)
-
Help files reformatted as HTML Help for compatibility with Vista. (NEW)
-
.PDF manual updated with latest product information. (NEW)
Version 5.37.000 of TracePlus®/Win32 includes the
following fixes and enhancements:
-
API functions may not be captured as expected because of previous changes to
the API hooking technology used by TracePlus. (FIXED)
-
Gathering File I/O and Registry information may cause issues in multithreaded
applications. (FIXED)
Version 5.35.000 of TracePlus®/Win32 includes the
following fixes and enhancements:
-
The maximum number of records displayed in the API View has been increased from
20,000 to 25,000. (NEW)
-
The maximum number of lines displayed in the Data View has been increased from
12,000 to 20,000. (NEW)
-
Added support for the Microsoft Extensions to the Winsock API. (NEW)
-
The base technology used to intercept Win32, Winsock, and WININET APIs has been
been updated for more stability and speed. (NEW)
-
The function InternetOpenURL() may cause the target application to crash if
long URLs were used. (NEW)
Version 5.32.000 of TracePlus®/Win32 includes the
following fixes and enhancements:
-
The Setup application was modified to install certain TracePlus menu items
under the "All Users" directory which means that they will appear for all user
accounts on the PC. Note that this feature can only be obtained by requesting a
new SETUP.EXE from the Support department. (NEW)
-
Updated to create, read, and write certain necessary files under limited user
accounts.. (NEW)
-
Patch updater would not patch properly licensed products due an error in
checking for a digital signature in previous versions of the product. (FIXED)
Version 5.30.000 included the following fixes and
enhancements:
-
Updated so that the product is compatible with 32 bit versions of Windows Vista
Home/Business/Ultimate Editions. (NEW)
-
The DLL which intercepts browser requests and responses has been modified for
faster execution and compatibility with Windows Vista. (NEW)
-
The
ability to intercept applications launched from the Start menu or
the Desktop will not be available in Windows Vista. The
implementation of his feature uses functionality available in
previous versions of Windows that was removed from Vista by
Microsoft because of security concerns.
-
The filtering
mechanism incorrectly caused some API functions not to be
displayed even though they were being captured in the target
application. (FIXED)
Version 5.20.000 included the following fixes and
enhancements:
-
Added support for the Winsock 1.1 API. (NEW)
-
Added support for the Winsock 2.0 API. (NEW)
-
Enhancements to the core API interception technology provide greater
compatibility with applications running on all Windows platforms. (NEW)
-
An application may crash when intercepted by TracePlus while running on a
HyperThreaded CPU (Intel processors only) on Windows XP or Windows 2003 Server.
(FIXED)
-
.TPA files created by version 5 of TracePlus may not load as expected. (MAJOR
FIX)
Version 5.15.000 included the following fixes and
enhancements:
-
The "Time" column in the Diagnostics View was expanded to two columns titled
"Called" and "Returned". This provides more infomation on API functions that
take a long time to complete. (NEW)
-
Added a /PROMPT option which can appear before an executable filename on the
TracePlus command line. This forces the Capture Settings dialog box to appear
before the application specified after the /PROMPT option is executed. This
option is useful when debugging NT services. (NEW)
-
The default behavior of the Capture Settings dialog box appearing when
TracePlus is launched with an executable filename specified on the command line
has been disabled. Use the /PROMPT directive before the application path if you
need the Capture Settings dialog box to appear. (NEW)
-
Random timing errors would occur when running TracePlus on a dual-processor PC
or a PC with a dual-core CPU. (FIXED)
-
Random hanging when exiting TracePlus may occur due to issues with waiting for
certain threads to terminate. (FIXED)
-
Applications may crash when running inside TracePlus when calling various
WININET API functions. (FIXED)
-
Removed the prompt to debug child processes since there already is a checkbox
for enabling this feature on the Launch Tab of the Capture Settings dialog box.
-
Pressing the Pause button on the toolbar in the main window would disable the
Stop button. (FIXED)
-
The splash screen logo would display when TracePlus was launched as a result of
double-clicking on a .TPA file in Windows Explorer. (FIXED)
-
The splash screen logo would display when launching a service with TracePlus. (FIXED)
-
The demo dialog box would display when specifying an application on the
TracePlus command line (only in demo versions of the product). (MODIFIED)
-
The demo dialog box would display when launching a service with TracePlus (only
in demo versions of the product). (MODIFIED)
-
Certain applications such as Java Applets launched from a Web Browser may
terminate unexpectedly. (FIXED)
-
When clicking on an .TPA file in Windows Explorer, it would be ignored if
TracePlus was already running. (FIXED)
Version 5.12.000 included the following fixes and
enhancements:
-
All 32-bit versions of Windows Vista supported with this release. (NEW)
-
Added a new menu item "View Online FAQ" to the Help menu. This will launch the
default browser with the URL of a new Frequently Asked Questions page
containing information on how to use the product. (NEW)
-
Added support for debugging Windows NT services. (NEW)
-
No records would appear in any of the views after receiving the "Do you want to
trace" message. (FIXED)
-
Child processes would not be debugged as expected. (FIXED)
-
Applications such as Microsoft Office 2003 may crash when exiting due to APIs
not being unhooked before TracePlus unloads. (FIXED)
-
Parameterized SQL statements may cause the target application to crash when
running in TracePlus. (FIXED)
-
Double-clicking on a .TPA file in a "My Computer" or Windows Explorer window
launches TracePlus but crashes before the file is loaded. (FIXED)
Version 5.05.000 included the following fixes and
enhancements:
-
Added a column labeled "Thread" containing the thread ID to the File I/O View.
(NEW)
-
Added a column labeled "Thread" containing the thread ID to the Registry View.
(NEW)
-
Added a column labeled "Thread" containing the thread ID to the Status View. (NEW)
-
Added a column labeled "Thread" containing the thread ID to the Registry View.
(NEW)
-
Updated the "Save as HTML" feature in all views to enhance the visual
presentation of the data. (NEW)
-
Updated the page layouts in all views that support the Print feature. (NEW)
-
Running TracePlus as a service would not launch the service specified on the
command line. (FIXED)
-
Launching TracePlus with an application specified on the command line would not
launch the application. (FIXED)
-
Saving a view as HTML would display an "not available in demo" message. (FIXED)
-
The API Colors tab in the Display Options dialog box would not save colors for
the specified items as expected. (FIXED)
-
The .CNT file was not installed with the application help file. (FIXED)
Release- Date: 6/15/2007 (Only for customers who have
version 4.x.x)
Version 4.40.000
|
The patch below will only update retail versions of TracePlus®/Win32
.
NOTE: If you are having problems installing the patch over your currently
installed version (listed below), follow the following procedure.
-
Uninstall the product you currently have installed (be sure you
have a copy of the original product you purchased).
-
Reinstall the original version you received when you purchased the
product.
-
Reapply the patch you downloaded from here.
|
HTTP
FTP
The updater will upgrade the following versions of TracePlus/Win32:
-
TracePlus/Win32 v4.01.000
-
TracePlus/Win32 v4.10.000
-
TracePlus/Win32 v4.12.000
-
TracePlus/Win32 v4.20.000
-
TracePlus/Win32 v4.21.000
-
TracePlus/Win32 v4.30.000
The patch includes all bug fixes up to 6/15/2007. We recommend that you apply
this patch so that TracePlus®/Win32 can operate at its maximum
efficiency.
To apply the patch, unzip this file to a temporary directory and run SETUP.EXE
from Windows.
|
If you cannot find the version number of your product in this list,
or the update does not work with your product, please e-mail
for a new copy of SETUP.EXE.
Please note that in order to receive a new copy of SETUP.EXE, you
must provide us with a copy of the original SETUP.EXE from your purchased copy
of the product.
|
Version History
Version 4.40.000 of TracePlus®/Win32 includes the
following fixes and enhancements:
-
Enhancements to the core API interception technology provide greater
compatibility with applications running on all Windows platforms. (NEW)
-
The Setup application was modified to install certain TracePlus menu items
under the "All Users" directory which means that they will appear for all user
accounts on the PC. Note that this feature can only be obtained by requesting a
new SETUP.EXE from the Support department. (NEW)
-
Updated to create, read, and write certain necessary files under limited user
accounts.. (NEW)
-
An application may crash when intercepted by TracePlus while running on a
HyperThreaded CPU (Intel processors only) on Windows XP or Windows 2003 Server.
(FIXED)
-
Random timing errors would occur when running TracePlus on a dual-processor PC
or a PC with a dual-core CPU. (FIXED)
-
Random hanging when exiting TracePlus may occur due to issues with waiting for
certain threads to terminate. (FIXED)
-
Applications may crash when running inside TracePlus when calling various
WININET API functions. (FIXED)
-
Certain applications such as Java Applets launched from a Web Browser may
terminate unexpectedly. (FIXED)
-
Added a new menu item "View Online FAQ" to the Help menu. This will launch the
default browser with the URL of a new Frequently Asked Questions page
containing information on how to use the product. (NEW)
-
Child processes would not be debugged as expected. (FIXED)
-
Applications such as Microsoft Office 2003 may crash when exiting due to APIs
not being unhooked before TracePlus unloads. (FIXED)
-
Parameterized SQL statements may cause the target application to crash when
running in TracePlus. (FIXED)
Version 4.30.000 included the following fixes and
enhancements:
-
Added 5 new API classes: Date and Time, Resource Management, System Related,
Timers, and Tokens. (NEW)
-
Filter Profiles would not be deleted correctly and would reappear in the
Profiles list. (FIXED)
Version 4.21.000 included the following fixes and
enhancements:
-
Improved inter-application communications between TracePlus and the target
applications resulted in a noticable speed increase of target applications. (NEW)
-
Internet Explorer 7 would crash when terminated under TracePlus. (FIXED)
-
Incorrect buffer allocation during calls to HttpSendRequestW() may cause the
target application to crash inside TracePlus. (FIXED)
Version 4.20.000 included the following fixes and
enhancements:
-
When running in a Terminal Server or Remote Desktop session, the default window
position assigned by Windows will be used instead of the saved window position.
(NEW)
-
The process of intercepting applications launched from Windows Explorer has
been modified so that changing directories within an Explorer view will not
cause the "Do you want to trace" prompt to appear. (NEW)
-
Added four new API functions VirtualProtect(), VirtualProtectEx(),
VirtualQuery(), and VirtualQueryEx(). (NEW)
-
An issue with HeapFree() API caused Microsoft Office 2003 to request product
code information even though the product was already activated. (FIXED)
-
Applications using MFC 7.0 and MFC 7.1 runtime libraries would crash when
terminated under TracePlus. (FIXED)
-
Java applications would crash in TracePlus due to a large number of flags being
passed to SetWindowPos(). (FIXED)
-
Fixed issues with the ODBC API where capturing SQL statements may cause access
violations in the target application. (FIXED)
-
Calls to EnumDependentServices() and EnumServiceStatus() functions would cause
the target application to crash if the number of services caused TracePlus to
allocate more than 32767 bytes. (FIXED)
-
Calls to EnumPrinters(), EnumJobs(), EnumPrinterDrivers(),
EnumPrintProcessors(), EnumPrintProcessorDataTypes() may cause target
application to crash due to incorrect handling of buffer size variables. (FIXED)
-
Incorrect handling of parameters to InternetCrackUrl() and InternetCreateUrl()
may cause data corruption in target applications. (FIXED)
-
InternetReadFile() did not display the number of bytes read via a pointer
paramter. (FIXED)
-
The DOCINFO structure passed to the StartDoc() function was not being
displayed. (FIXED)
-
Various structures used by various RAS APIs would not display as expected. (FIXED)
-
Streaming video from sites such as ESPN or CNN may playback incorrectly while
running inside TracePlus. (FIXED)
Version 4.12.000 included the following fixes and
enhancements:
-
Added option to the Launch Tab of the Capture Settings dialog box which enables
the capturing of applications launched from a command prompt (NT 4.x/2000/XP
only). (NEW)
-
Added option to the Launch Tab of the Capture Settings dialog box which
disables the capturing of child processes spawned from the target process. (NEW)
-
Performance enhancements show a noticeable increase in execution speed for
target applications. (NEW)
-
Fixed a problem where TracePlus would crash with an access violation on startup
if DEP support was enabled in Windows XP SP2 and Windows 2003 Server SP1. This
problem is most likely to occur on PCs with AMD Athlon 64 Family processors, as
well as newer Intel Xeon, Pentium 4, Pentium M or "Centrino" processors, and
Celeron-D processors. (MAJOR FIX)
Release Date: 8/5/2005 (Only for customers who have
version 3.x.x)
|
The patch below will only update retail versions of TracePlus®/Win32
.
NOTE: If you are having problems installing the patch over your currently
installed version (listed below), follow the following procedure.
-
Uninstall the product you currently have installed (be sure you
have a copy of the original product you purchased).
-
Reinstall the original version you received when you purchased the
product.
-
Reapply the patch you downloaded from here.
|
HTTP
FTP
The updater will upgrade the following versions of TracePlus/Win32:
-
TracePlus/Win32 v3.00.001
-
TracePlus/Win32 v3.02.000
-
TracePlus/Win32 v3.04.001
-
TracePlus/Win32 v3.05.000
-
TracePlus/Win32 v3.06.000
-
TracePlus/Win32 v3.06.001
-
TracePlus/Win32 v3.10.000
-
TracePlus/Win32 v3.20.000
-
TracePlus/Win32 v3.50.000
-
TracePlus/Win32 v3.52.000
-
TracePlus/Win32 v3.53.000
-
TracePlus/Win32 v3.54.000
-
TracePlus/Win32 v3.60.000
The patch includes all bug fixes up to 8/5/2005. We recommend that you apply
this patch so that TracePlus®/Win32 can operate at its maximum
efficiency.
To apply the patch, unzip this file to a temporary directory and run SETUP.EXE
from Windows.
|
If you cannot find the version number of your product in this list,
or the update does not work with your product, please e-mail
for a new copy of SETUP.EXE.
Please note that in order to receive a new copy of SETUP.EXE, you
must provide us with a copy of the original SETUP.EXE from your purchased copy
of the product.
|
Version History
Version 3.65.000 of TracePlus®/Win32 includes the
following fixes and enhancements:
-
Fixed a CPU usage issue when tracing an application emitting large amounts of
API information. (FIXED)
-
Added support for the ACL (Security) API. This includes the following API
functions: (NEW)
| BuildExplicitAccessWithName() |
GetEffectiveRightsFromAcl() |
LookupSecurityDescriptorParts() |
| BuildImpersonateExplicitAccess WithName()
|
GetExplicitEntriesFromAcl() |
SetEntriesInAccessList() |
| BuildSecurityDescriptor() |
GetMultipleTrusteeOperation() |
SetEntriesInAcl() |
| BuildTrusteeWithName() |
GetNamedSecurityInfo() |
SetEntriesInAuditList() |
| BuildTrusteeWithSid() |
GetNamedSecurityInfoEx() |
SetNamedSecurityInfo() |
| CancelOverlappedAccess() |
GetOverlappedAccessResults() |
SetNamedSecurityInfoEx() |
| ConvertAccessToSecurityDescriptor() |
GetSecurityInfo() |
SetSecurityInfo() |
| ConvertSecurityDescriptorToAccess() |
GetSecurityInfoEx() |
SetSecurityInfoEx() |
| ConvertSecurityDescriptorToAccess Named()
|
GetTrusteeForm() |
|
| GetAccessPermissionsForObject() |
GetTrusteeName() |
|
| GetAuditedPermissionsFromAcl() |
GetTrusteeType() |
|
-
Expanded support for the RAS API. This includes the following API functions: (NEW)
| RasClearConnectionStatistics() |
RasGetAutodialParam() |
RasHangUp() |
| RasClearLinkStatistics() |
RasGetConnectionStatistics() |
RasInvokeEapUI() |
| RasConnectionNotification() |
RasGetConnectStatus() |
RasRenameEntry() |
| RasCreatePhonebookEntry() |
RasGetCountryInfo() |
RasSetAutodialAddress() |
| RasDeleteEntry() |
RasGetCredentials() |
RasSetAutodialEnable() |
| RasDeleteSubEntry() |
RasGetCustomAuthData() |
RasSetAutodialParam() |
| RasDial() |
RasGetEapUserData() |
RasSetCredentials() |
| RasEditPhonebookEntry() |
RasGetEapUserIdentity() |
RasSetCustomAuthData() |
| RasEnumAutodialAddresses() |
RasGetEntryDialParams() |
RasSetEapUserData() |
| RasEnumConnections() |
RasGetEntryProperties() |
RasSetEntryDialParams() |
| RasEnumDevices() |
RasGetErrorString() |
RasSetEntryProperties() |
| RasEnumEntries() |
RasGetLinkStatistics() |
RasSetSubEntryProperties() |
| RasFreeEapUserIdentity() |
RasGetProjectionInfo() |
|
| RasGetAutodialAddress() |
RasGetSubEntryHandle() |
|
| RasGetAutodialEnable() |
RasGetSubEntryProperties() |
|
-
The Activation Wizard now offers three ways to activate your product: Direct
(via the Internet), e-Mail, and via our Web site. (NEW)
-
Fixed a buffer overflow issue when an application called InternetQueryOption()
which would cause the application crash when running inside TracePlus. (FIXED)
-
Increased the buffer sizes of many API functions intercepted by TracePlus due
to spurious buffer overflows that may cause an application to crash inside
TracePlus. (FIXED)
-
Functions that do not take a file handle in the File I/O View now display
"(none)" instead of the number 0. (FIXED)
-
The Printer option available in the Options dialog box on the Trace menu has
been removed.
Version 3.54.000 included the following fixes and
enhancements:
-
The progress bar would not calculate the correct number of records when
exporting the contents of all Views. (FIXED)
-
Reading records from an RDF file and specifying a specific starting record
number may not work as expected if the API View was sorted before the RDF file
was created. (FIXED)
-
Removed the ability to log File Read/Write operations in the File I/O view due
to CPU load and the determination that it was of limited usefulness.
-
The sequence number of SQL statements was not being formatted according to the
current locale. (FIXED)
-
The start time and elapsed time of SQL statements was not being formatted
according to the current locale. (FIXED)
Version 3.53.000 included the following fixes and
enhancements:
-
The status of objects created by CoCreateInstance() and CoCreateInstanceEx() is
now displayed in the Status View. (NEW)
-
Added support for the function CoCreateInstanceEx(). (NEW)
-
When launching an application from TracePlus, quotes would always be placed
around any specified command-line parameters. (FIXED)
-
Values in the Registry Window were always displayed as REG_SZ if the
RegEnumValues() function was called. (FIXED)
-
The application would crash if an .RDF file was imported that was created with
the same version of the application (affects 3.52.000 only). (MAJOR FIX)
-
The Status Window would not display process names and a spurious tab character
would appear when an .RDF file was imported. (FIXED)
-
Improved indexing technique when intercepting API functions resulted in a 20%
speed increase of target applications. (NEW)
-
Intermittent memory allocation failures under heavy load may cause the target
application to crash. (FIXED)
-
The international date, time, and numeric formatting can be reset to English
(United States) by selecting "Use English (U.S.) Formatting" from the View
menu. This feature is enabled only if the user locale specified in Windows is
OTHER than English (United States). (NEW)
Version 3.50.000 included the following fixes and
enhancements:
-
Supports the date, time, and numeric formats of over thirty countries:
| Australia |
France |
New Zealand |
| Austria |
Germany |
Norway |
| Belgium |
Iceland |
Paraguay |
| Bolivia |
Indonesia |
Philippines |
| Brazil |
Ireland |
Portugal |
| Canada |
Italy |
South Africa |
| Chile |
Jamaica |
Sweden |
| Colombia |
Liechenstein |
Switzerland |
| Denmark |
Malaysia |
United Kingdom |
| Finland |
Mexico |
Venezuela |
(NEW)
-
Created a tabbed window inside the SQL Statements View and added a new File I/O
View, which displays descriptions of file I/O activity that takes place inside
an application. File I/O activity includes mapped files as well. The File I/O
View is active whether or not any of the supported API functions are selected
in the Filters dialog box. (NEW)
-
Now compatible with .NET Web Services, ASP.NET, HTML Applications (HTAs), .NET
Remoting, and applications written for the .NET Framework. (NEW)
-
The API View has been renamed as the "Diagnostics View".
-
A "Maximize Pane" feature has been added to the Diagnostics View. (NEW)
-
A "Restore Panes" feature has been added to the Diagnostics View. (NEW)
-
When writing .RDF files, TracePlus was opening and closing the file after each
record was written, creating long wait times for large amounts of records to be
written. (MAJOR FIX)
-
When "Clear all Views" was selected, the Details View (the lower half of the
Diagnostics View) would not be cleared. (FIXED)
-
Disable application debugger detection feature will prevent the application
from detecting that it is being run in a debugger. Some well known applications
have code in them that prevent applications such as TracePlus from revealing
the way that they operate. Such applications abort immediately after they are
launched, or disable certain features of the application when a debugger is
detected. (NEW).
-
Uses Windows XP colors and styles (theme) when running under Windows XP. (NEW)
Version 3.10.000 included the following fixes and
enhancements:
-
Disable application debugger detection feature will prevent the application
from detecting that it is being run in a debugger. Some well known applications
have code in them that prevent applications such as TracePlus from revealing
the way that they operate. Such applications abort immediately after they are
launched, or disable certain features of the application when a debugger is
detected. (NEW).
-
Uses Windows XP colors and styles (theme) when running under Windows XP. (NEW)